Experimental Investigation and Performance Evaluation of Concrete Roof Cooling using Pulsating Heat Pipes
Contributors
Dr. Trijo Tharayil
Mohammad Israr
Keywords
Proceeding
Track
General Track
License
Copyright (c) 2026 Sustainable Global Societies Initiative

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Abstract
Most of the houses and buildings have concrete roof. One of the major disadvantage with concrete roof is it absorbs solar heat during day time. This leads to a roof temperature of 60-70oC. This hot roof causes thermal discomfort to occupants as the heat is radiated downwards. People use coolers or air conditioners to overcome this discomfort. Methods such as green roof, cool roof etc are suggested by researchers as a solution to this problem. However, there are many disadvantages to these methods. Hence pulsating heat pipes (PHP) integrated into concrete roof are proposed in this study. The effect of pulsating heat pipes in heat transfer from concrete slabs are investigated in this study under various operating conditions such as different filling ratios, number of heat pipes, inclination angles and working fluids. The experimental results suggest 50% as the optimum filling ratio for pulsating heat pipe. Similarly double layer of PHP offers better heat transfer compared to single layer. As inclination from horizontal increases, thermal performance also increases. An optimum volume fraction of 0.045% is observed with nanofluid for optimum performance. The experimental results suggest PHP as a promising solution for concrete roof cooling.